h6. [[Econet]] h6(. » [[Econet SWI Calls|SWI Calls]] h6((. » Econet_StartImmediate h2. Econet_StartImmediate h5. (SWI &40016) |_<^{width:4em}. Entry | | |<^. R0 |<^. "Operation type":Econet%20Technical%20Details#immediate | |<^. R1 |<^. Remote address, or procedure number | |<^. R2 |<^. Station number | |<^. R3 |<^. Net number | |<^. R4 |<^. pointer to data buffer | |<^. R5 |<^. Data size | |<^. R6 |<^. Repeat count | |<^. R7 |<^. Delay (in centi-seconds) | |_<^{width:4em}. Exit | | |<^. R0 |<^. Handle | |<^. R1 |<^. Corrupted | |<^. R2 |<^. Pointer to buffer | |<^. R3 |<^. Station number | |<^. R4 |<^. Net number (or 0 if R3 on entry was the local net) | h4. Use The purpose of this call is to create a TxCB and starts an immediate operation. h4. Notes The data buffer should be in RMA or some other permanently available area of memory, due to the way in which the data is read. This SWI is re-entrant. h4. See also * [[Econet Technical Details]] * [[Econet_DoImmediate]]