Entry | |
---|---|
R0 | 3 |
R1 | Pointer to module name plus any parameters for initialisation |
Exit | |
---|---|
R0 | Preserved |
R1 | Preserved |
The purpose of this call is to reinitialise a module.
A Module is reinitialised by calling its Finalise address, releasing any workspace and then calling its Initialisation address.
If the module refuses to reinitialise, it is removed from RMA.