Showing changes from revision #1 to #2:
Added | Removed | Changed
Entry | |
---|---|
R0 | 15 (&0F) |
R1 | Pointer to block, and containing: |
+0 | 24 (reason code) |
+1 | Date and time string in local language |
Exit | |
---|---|
R0 | Preserved |
R1 | Preserved |
The purpose of this call is to set the date and time in the CMOS clock and its soft copy.
This OS_Word sets the date and time in the CMOS clock and its soft copy. The string format is territory dependant – for the UK (and RISC OS 2) it is of the form
Day,DD MMM YYYY.HH:MM:SS
is equivalent to Mon,17 Feb 1992.17:35:04.